Wavecom GSM Modem
This confidential document is the property of WAVECOM and may not be copied or circulated without permission
61
10.2. Setting up the PC fax application:
The recommended fax application is Delrina WinFax v4.0.
It should be configured as follows (menu Setup/Fax Modem Setup) :
Port: com 1
Model: Generic Class 1 (HARDWARE FLOW CONTROL). Above
all, do not select « Generic Class 1 » (Software flow control).
Init: clear default string
Reset: clear default string
Maximum Transmit Rate: 9600 baud.
Others settings are of no interest for the GSM unit: they can be modified.
10.3. Restoring the module's default profile for data call.
If the module is configured as stated in 1/ then the serial rate is 2400
baud which of course limits the overall thoughput in support of 4800/9600
data calls.
Therefore, the serial rate should be set back to 9600 (or better 19200)
baud by issueing: AT+IPR = 9600; &W <enter>